Automated microarray rapid test for detecting SARS-CoV-2 antibodies

Versatile and reliable SARS-CoV-2 antibody assay

During the continued progression of the Corona pandemic, rapid, inexpensive, and reliable tests will become increasingly important to determine whether people have the associated antibodies – either through infection or vaccination. Researchers at the Technical University of Munich (TUM) have now developed such a rapid antibody test. It provides the result in only eight minutes; the aim is to further reduce the process time to four minutes.

Lead author Julia Klüpfel with a measuring chip at the laboratory of TranslaTUM. S. Kissel / TUM
Lead author Julia Klüpfel with a measuring chip at the laboratory of TranslaTUM.

There are currently more than 20 different test procedures available for determining whether a person has antibodies against the new Corona virus. The waiting times for the results range between ten minutes and two and a half hours.

Matrix effects reduce the sensitivity of many of the methods. The more sensitive assays require numerous steps, making them expensive. In addition, most tests can identify only a single kind of antibody, forcing a choice between testing either for immunity through vaccination or through survived infection.

An interdisciplinary research team at the Technical University of Munich, led by the Chair of Analytical Chemistry and Water Chemistry, has now developed a low-cost automated rapid test that is highly sensitive and highly specific in detecting the three most important antibodies. The project, called CoVRapid, was funded by the Bavarian Research Foundation.

Modification of a proven process

The measurement is carried out on a foil-based sensor chip using the MCR microarray analysis platform of the Munich-based supplier GWK Präzisionstechnik GmbH. The device displays its measurement results within a few minutes after injecting a blood sample.

Today, the procedure still takes eight minutes, but building on current research, the waiting time will soon be reduced to just four minutes. IgG antibodies against a protein fragment of the SARS-CoV-2 receptor binding domain (RBD), the spike protein (S1 fragment) and the nucleocapsid protein (N) are simultaneously analyzed.

Deployable against new mutants

New mutant proteins can be very easily integrated into the chip. For this project, the research team is collaborating with the Planegg-based company ISAR Bioscience, which produces the respective viral proteins biotechnologically and modifies them for analytical use. The process used to fix the proteins onto the sensor chip has been tried and tested for many years.

"We have already developed reliable rapid tests for antibiotics in milk and for Legionella using this technology platform," says adjunct teaching professor Dr. Michael Seidel, head of the Bioanalytics and Microanalytical Systems group at TUM's Department of Analytical Chemistry and Water Chemistry. "The system has already proven itself in practical use. Our ‘CoVRapid’ rapid test may thus be deployed in clinics, medical offices and research laboratories in the very near future."

The new test will answer questions about corona immunity

However, the new rapid test can do even more: the microarray technology, which allows to accommodate up to 100 measurement points on a single chip, is so sensitive that it can even determine the concentration of antibodies in a sample.

"The present research begs questions like: How well do vaccinations work? How long does immunity last? When will vaccinations need to be readministered? With its high sensitivity, our CoVRapid will help us find the answers to these questions," says lead author Julia Klüpfel.

In the long term, the team is also planning on including other pathogens in the panel so the assay can be used, for example, to evaluate the effectiveness of an influenza vaccination.

Publications

Klüpfel, J.; Koros, R.; Dehne, K.; Ungerer, M.; Würstle, S.; Mautner, J.; Feuerherd, M.; Protzer, U.; Hayden, O.; Elsner, M.; Seidel, M.
Automated, flow-based chemiluminescence microarray immunoassay for the rapid multiplex detection of IgG antibodies to SARS-CoV-2 in human serum and plasma (CoVRapid CL-MIA)
Analytical and Bioanalytical Chemistry, 13.05.2021 – DOI: 10.1007/s00216-021-03315-6

Further information and links

In addition to the Chair of Analytical Chemistry and Water Chemistry (Prof. Elsner) and the associated Bioanalytics and Microanalytical Systems Group (PD Dr. Seidel), the Institute of Molecular Immunology and Experimental Oncology (Prof. Knolle), the Institute of Virology (Prof. Protzer) and the Heinz Nixdorf Chair of Biomedical Electronics (Prof. Hayden) were involved in the project.

The CoVRapid project is funded by the Bavarian Research Foundation (AZ-1438-20C). The microarray analysis platform MCR 3 and its successor generation, MCR-R were made available by the Munich-based company GWK Präzisionstechnik GmbH. Recombinant antigens were produced by ISAR Bioscience. Safety-relevant steps were performed in the biosafety laboratory of the Central Institute for Translational Cancer Research (TranslaTUM).

High resolution images

Technical University of Munich

Corporate Communications Center

Contacts to this article:

PD Dr. Michael Seidel
Chair of Analytical Chemistry and Water Chemistry
Technical University of Munich
Elisabeth-Winterhalter-Weg 6, 81377 Munich, Germany
Tel.: +49 89 289 78252 – E-Mail: michael.seidelspam prevention@mytum.de

Back to list

News about the topic

HSTS